Why Static Lighting Strategies Won’t Survive the Next Decade

Ready to get started?

Summary

Charlie BensonMost supplemental lighting in greenhouses is still controlled open-loop where output is decided in advance from a fixed schedule, a seasonal dimming profile or a weather forecast. Over 31 days in autumn 2026, we measured how far forecast-driven control, the most advanced of these, diverged from the daylight actually reaching the crop in a UK greenhouse.

The forecast’s mean error was just +0.05 mol/m²/day, but its mean absolute error was 1.47 mol/m²/day.

On 14 of 31 days, it missed by more than 1 mol/m²/day.

This piece sets out why that gap matters, why it can’t be closed by better calibration, and why the next step is control that combines forecasts, live canopy measurement and the plant’s own photosynthetic response.

 

Static control is open-loop control

In control terms, a static lighting strategy is an open-loop one. Output is set from a plan, and nothing measured at the crop feeds back to correct it. Fixed photoperiods, seasonal dimming profiles and forecast-driven setpoints share this structure; they differ only in how good the plan is.

A closed-loop strategy measures what the crop actually receives and adjusts supplemental output to hold a target. In this piece, light at the crop is measured as ePAR (extended PAR, 400–800nm on our sensors), which includes far-red. The distinction matters because the objective is not a lamp output. It is a daily light integral (DLI) at the canopy, made up of variable natural light plus supplemental light.

Open-loop control fixes the variable you can control and leaves the one you can’t to chance. The result is lamp output that behaves predictably, and a crop light environment that doesn’t.

Five levels of lighting control

Lighting control can be described as five levels of maturity. In our experience, most installed systems operate at levels 1 to 3.

Levels 1 to 3 are open-loop. Level 4 closes the loop on light. Level 5 closes it on light and the plant.

The value of closing the loop on light is well established. Adaptive LED control that adjusts supplemental output to measured sunlight to hold a target DLI has reported electricity cost reductions of 20–92% (van Iersel & Gianino, reviewed in Jayalath et al., 2024), in a sector where supplemental lighting accounts for 10–30% of greenhouse operating costs.

Closed-loop control brings its own engineering requirements: calibrated ePAR sensors positioned to represent the canopy, and fixtures and drivers that dim smoothly and quickly enough to follow passing cloud.

Forecast vs measured: what the data shows

Between 14 September and 14 October 2026, we compared forecast daylight DLI, calculated at the start of each photoperiod, with daylight DLI measured inside a UK greenhouse. The same light transmission factor was applied to the forecast every day.

Judged by its average, this forecast was near perfect. But the crop experiences each day, not the average, and the same averaging is what makes seasonal dimming profiles look adequate on paper.

Why the error can’t be calibrated out

A systematic error, such as an incorrect transmission factor, would bias the forecast consistently in one direction. That is not what we observed. The mean error was effectively zero, the large errors split almost evenly between over- and under-forecasts, and the same fixed transmission factor produced both the accurate days and the worst ones. The error is random day-to-day variance in the weather data, not bias, so no correction factor can remove it.

There is also a physical reason. Actual greenhouse transmission varies with solar elevation, the ratio of direct to diffuse radiation, screen position and condensation. Any single correction factor will miss on the days those conditions shift.

Our result is consistent with the solar forecasting literature. Day-ahead irradiance forecast error scales with how variable cloud cover is at a site (Lauret et al., 2025). Numerical weather models also resolve cloud far more coarsely than the minute-to-minute changes a greenhouse experiences (KNMI). Sites with frequent broken cloud are where forecasts struggle most, and they are also where supplemental lighting matters most.

The cost of each error direction:

Over-forecast (8 days): the expected daylight didn’t arrive. Supplemental output was held back, and the crop fell short of its DLI target.

Under-forecast (6 days): more daylight arrived than planned. Supplemental light was delivered on top of light the crop already had, at a lower marginal photosynthetic return, consuming unnecessary energy.

Hardware has moved faster than control

charlie benson

 

Greenhouse lighting hardware has changed more in the last decade than in the three before it. Growers have moved from HPS, where control was effectively on or off, to dimmable LEDs, and increasingly to multichannel fixtures that vary intensity and spectrum independently. Each step multiplied the control variables: from one switch to one output level, to an output level per channel at any point in the photoperiod.

Control strategy has not kept pace. In many facilities I visit, multichannel fixtures run at 100% on every channel by default, on a fixed schedule. That is level 1 control on hardware built for levels 4 and 5, and the capability that justified the investment goes unused.

This is not a failing of growers. A multichannel fixture exposes far more decisions than can be managed by hand, and few growers have been given a framework for making them. With a harvest at stake, full output on every channel is the rational default. The industry, suppliers included, has delivered the capability faster than the means to use it.

Climate computer integration is often positioned as the solution, and bringing lighting and climate together is the right direction. But in many installations, the climate computer drives the LEDs with the same static schedules and the same commands a standalone controller would send. The grower pays a premium for integration but gains little control capability. Integration only adds value when the control behind it advances.

This has implications for LED manufacturers as well as growers. As fixture efficacy approaches its physical limits, the remaining gains in cost per useful mol will increasingly come from how fixtures are controlled rather than how they are built. Manufacturers not developing closed-loop or plant-response control in-house will likely need to partner with automation specialists who are. Otherwise, their most capable hardware will continue to be installed and run as level 1 equipment.

Two efficiency gains static control leaves unused

Dynamic control saves more energy than the dimmed fraction alone suggests. Two effects compound: dimmed LEDs convert electricity to photons more efficiently, and supplemental spectrum can be weighted against what the sun already provides.

Dimming can raise efficacy

LED efficacy falls as drive current rises, a loss known as current droop, and higher drive current also raises junction temperature, adding thermal droop (Kusuma, Pattison & Bugbee, 2020). Lowering the drive current therefore increases µmol/J (Bugbee, Greenhouse Grower). A fixture dimmed to 60% of its photon output draws less than 60% of its full electrical power, so the energy saving exceeds the dimming percentage.

Two engineering caveats apply. The gain comes from constant-current (analogue) dimming; PWM dimming switches the LEDs at full current, so efficacy during each pulse does not improve. And at very low drive currents, LED and driver efficiency both fall, so the benefit has a practical floor. Fixture and driver design across the full dimming range is part of what makes dynamic control pay off.

Weighting spectrum against sunlight

Sunlight already supplies a broad spectrum, rich in blue and green wavelengths. When solar radiation is ample, supplemental output can be weighted towards red. Red photons carry less energy than blue photons, and red LEDs achieve higher photon efficacy (µmol/J) than the blue and phosphor-converted white LEDs typically used in horticulture. Each joule of electricity therefore delivers more photons.

The crop still receives the intended total spectrum, solar plus supplemental, at a lower electrical cost. Combined with the efficacy gain from dimming, this means the target light level and spectrum at the canopy can be reached with considerably less energy. Neither gain is available to an open-loop schedule, because it does not know how much sunlight is reaching the crop at any moment.

Why control accuracy matters more each year

Three trends are increasing the cost of open-loop error:

The value of a photon depends on when it is delivered. Time-of-use and dynamic electricity tariffs, grid flexibility payments, and on-site solar and storage all make the cost of supplemental light vary through the day. Control that cannot tell whether the crop needs light at a given moment cannot exploit that variation.

Photosynthetic return per photon is not constant. The quantum yield of photosystem II falls as PPFD rises (Elkins & van Iersel, 2018), so supplemental light added during low sunlight is used more efficiently than the same light added to a bright period. In one modelling study, constant supplemental light at 140 µmol/m²/s for 12 hours, in effect a level 1 strategy, was the least efficient scenario tested (Weaver & van Iersel, 2017). Placing light where its marginal return is highest requires knowing what the crop is already receiving.

Control complexity has outgrown manual management. Multichannel spectrum, variable tariffs and fluctuating daylight create more decisions per day than any grower can make by hand. They have to be automated.

In this context, a mean absolute error of 1.47 mol/m²/day is not a rounding issue. It is energy bought at the wrong time, or DLI lost on the day it was needed. The relevant metric shifts from cost per fixture to cost per mol the crop can actually use.

The next step: lighting led by photosynthesis

Closing the loop on light (level 4) solves the problem in our data. The crop receives its target DLI regardless of forecast error. But the target itself is still a fixed number, set in advance from crop guidelines or the grower’s preference. It assumes the plant’s capacity to use light is the same every day.

In practice, photosynthetic capacity varies with temperature, CO₂ concentration, vapour pressure deficit, crop stage and plant stress. A DLI target that is optimal one day can be wasteful or limiting the next.

The goal for the next generation of control is to measure the plant’s photosynthetic rate accurately at scale and align supplemental light to it. That requires three inputs working together:

Forecast (feedforward): anticipates the day’s natural light and energy prices, so lighting can be planned around both.

Live canopy ePAR (feedback): corrects in real time for what the forecast gets wrong, which our data shows is frequent.

Photosynthetic rate (target-setting): shows how efficiently the crop is converting light at that moment. Output can rise when the marginal return per photon is high, and fall when the plant is approaching light saturation or is limited by something other than light, such as CO₂ or stomatal closure.

In control engineering terms, this is closest to model predictive control: a forecast-based plan for the day, continuously corrected by measurement, optimising towards an objective set by the plant rather than a fixed number.

The difficulty is measurement. Leaf gas exchange measures carbon assimilation directly, but it is a leaf-level research method and impractical at crop scale. Chlorophyll fluorescence-based sensors are better suited to commercial deployment, but they estimate photosynthetic electron transport rather than carbon fixation, and the relationship between the two shifts with conditions. Making plant-derived signals accurate and robust enough to drive lighting decisions is the core technical challenge, and why we see this as the next step rather than a solved problem.

The principle has already been demonstrated. Researchers at the University of Georgia built a chlorophyll fluorescence biofeedback system that adjusted LED output in real time to hold a target electron transport rate (van Iersel, Weaver & Martin, 2016). Control was more precise at lower ETR targets and attempts to control on quantum yield alone were unstable. Those trials ran in controlled environments; making the approach work across a commercial canopy under fluctuating sunlight is the step still to be made.

Where Bloemteknik is

Our control systems operate at level 4 today. Advanced algorithms respond to measured conditions every two minutes, managing PPFD and spectrum within a defined photoperiod and keeping DLI within a minimum and optimal target range. Lamp output varies continuously so that the crop’s light environment doesn’t.

Our development work is focused on level 5: integrating plant-response sensing so that lighting targets are informed by photosynthetic activity and connecting lighting control with climate data so that lighting decisions account for temperature and CO₂.

Conclusion

Static, open-loop lighting strategies made sense when fixtures could only be switched on and off and electricity cost the same at every hour. Neither is true any longer. Forecast-driven control is a step forward, but our data shows its daily error is large, random and impossible to calibrate out. Measured closed-loop control removes that error today. Aligning light to the plant’s photosynthetic rate, using forecast, canopy measurement and plant sensing together, is the step that I believe will define the next decade.

 

About the data

Single UK greenhouse, 14 September–14 October 2026 (31 days). Forecast daylight DLI was calculated at photoperiod start, with a fixed transmission factor applied throughout, and compared with daylight DLI measured inside the greenhouse.

Error = forecast − measured. Single-day DLI values are rounded.

 

Sources

Jayalath, van Iersel & Ferrarezi (2024), Plants: supplemental lighting energy and adaptive control

Elkins & van Iersel (2018), ASHS: longer photoperiods and daily electron transport

Weaver & van Iersel (2017), ASHS: chlorophyll fluorescence models of lighting efficiency

van Iersel, Weaver & Martin (2016), JASHS 141(2): chlorophyll fluorescence biofeedback lighting control

Lauret et al. (2025), ISES Solar World Congress: day-ahead solar forecast error and site variability

KNMI: forecasting minute-scale irradiance variability from numerical weather predictions

Kusuma, Pattison & Bugbee (2020), Horticulture Research: From physics to fixtures to food, current and potential LED efficacy

Bugbee, Greenhouse Grower: Shedding light on LED tech

Breaking Boundaries

Straight answers to the questions we hear most often from cannabis growers
Straight answers to the questions we hear most often from cannabis growers

Latest News

Bloemteknik supplies its Top Crop 4 LED fixtures and GreenFingers™ adaptive lighting platform for a new
Bloemteknik's GreenFingers™ platform gets more funding support to revolutionise greenhouse lighting controls.
greenhouses aerial
GET in touch

Get a free consultation and business case calculation